CSP−900RMM−2 MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 204
Revision 34
05-20-20
Table 202. Airframe Periodic Inspection — Area 1, Nose Section and Cockpit (Cont.)
Registration No. Serial No. Helicopter Total Hours
Model InitialRMM SectionRequirement
Environmental Control System
900 Examine crew gaspers for correct operation and installation. 21−20−00
If optional heat/defog system is installed:
900 Examine heat/defog system:
Valve for condition and security
Ejector and ducts for condition and security.
21−40−00
If optional heat/defog system is installed:
900 Do a check of crew heater control cable for correct operation. 21−40−00
Fuel System
900 Do the “Fuel Shut−Off Valve Operational Test”. 28−00−00
900 Do the “Crossfeed Shut−Off Valve Operational Test (900 CONFIG)”. 28−00−00
Fire Protection
If optional bleed air leak detection system is installed:
900 Examine detection control units and electrical connections for
condition and security.
26−10−20
Instruments
900 Remove glare shield and top panel, and visually inspect:
Glare shield and top panel for condition and damage
Installation of electrical wiring and instrument connections for
condition, damage, and correct installation
Installation of pitot−static tubing and connections for condition,
damage, and correct installation.
95−00−00
95−10−00
95−20−00
and
CSP−SPM
20−60−00
900 Examine instrument panel and console structure for condition,
damage, and security of attach hardware.
53−20−00
95−00−00
900 Examine instruments for proper markings, condition, correct
operation, and security.
95−10−00
95−20−00
900 Examine area electrical wiring installation in forward section of
console and installation of forward interconnect panel.
96−00−00
and
CSP−SPM
20−60−00
900 Examine installation of console installed control panels and avionics
equipment for correct markings, condition, and security.
96−00−00