CSP900RMM2MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 209
Revision 28
05-20-50
Table 202. Inspection 1 Nose Section and Cockpit (Area 1) (Cont.)
Registration No. Serial No. Helicopter Total Hours
Model InitialRMM SectionRequirement
Instruments
900 Remove instrument panel glareshield and top panel. Visually inspect:
glareshield and top panel for condition and damage
Installation of electrical wiring and instrument connections for
damage and correct installation
Installation of pitotstatic tubing and connections for condition and
correct installation.
950000
951000
952000
CSPSPM
206000
900 Inspect instrument and console structure for condition and security of
attach hardware.
950000
532000
900 Inspect instruments for correct markings, condition, correct operation,
and security.
951000
952000
900 Inspect installation of console installed control panels and avionics
equipment for correct markings, condition, and security.
960000
Electrical Power
900 Inspect nose area electrical wiring installation and installation of
electrical panels for condition, security, support, and security of
hardware.
980000
CSPSPM
206000
If battery is installed in the nose:
900 Inspect battery installation
battery case and cover for condition, and damage, and installation
hardware for correct installation
vent tubes for condition and correct installation
power connection and temperature sensor connection for condition
and security.
961000
900 Inspect external power box or external power relay for condition,
correct installation, and security of wiring and electrical connections.
960000