CSP−900RMM−2MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 209
Revision 28
05-20-50
Table 202. Inspection 1 − Nose Section and Cockpit (Area 1) (Cont.)
Registration No. Serial No. Helicopter Total Hours
Model InitialRMM SectionRequirement
Instruments
900 Remove instrument panel glareshield and top panel. Visually inspect:
glareshield and top panel for condition and damage
Installation of electrical wiring and instrument connections for
damage and correct installation
Installation of pitot−static tubing and connections for condition and
correct installation.
95−00−00
95−10−00
95−20−00
CSP−SPM
20−60−00
900 Inspect instrument and console structure for condition and security of
attach hardware.
95−00−00
53−20−00
900 Inspect instruments for correct markings, condition, correct operation,
and security.
95−10−00
95−20−00
900 Inspect installation of console installed control panels and avionics
equipment for correct markings, condition, and security.
96−00−00
Electrical Power
900 Inspect nose area electrical wiring installation and installation of
electrical panels for condition, security, support, and security of
hardware.
98−00−00
CSP−SPM
20−60−00
If battery is installed in the nose:
900 Inspect battery installation
battery case and cover for condition, and damage, and installation
hardware for correct installation
vent tubes for condition and correct installation
power connection and temperature sensor connection for condition
and security.
96−10−00
900 Inspect external power box or external power relay for condition,
correct installation, and security of wiring and electrical connections.