CSP−900RMM−2 MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 226
Revision 28
05-20-50
Table 207. Inspection 6 − Baggage Compartment (Area 6) (Cont.)
Registration No. Serial No. Helicopter Total Hours
Model InitialRMM SectionRequirement
Anti−Torque Assembly
900 Inspect felt metal seal:
correct fan blade tip clearance
felt seal for indication of FOD damage.
64−30−00
Anti−Torque Flight Controls
900 Inspect anti−torque flight controls brackets, bellcranks, links and
control rods for condition, indication of interference, correct
installation, and rod end bolts installed in the correct direction.
67−20−00
Environmental Control System
If optional air conditioning is installed:
900 EARLY CONFIG − Inspect, condenser, refrigerant tubes, condenser
attach hardware, and condenser blowers, for condition and security.
21−50−00
Fire Protection
If optional heat/defog system is installed:
900 Inspect area detection cable and cable attachments for condition and
security of installation.
26−10−10
If optional fire extinguishing system is installed:
900 Inspect fire bottles and mounting brackets for condition and correct
installation. Do a check for correct charge pressure.
26−20−00
900 Inspect fire bottle discharge and cross−flow tubes for condition and
security of end connections.
26−20−00
Fuel System
900 Do the “Fuel Supply Vapor Shroud Leak Check/Pressure Test”. 28−00−00
If optional fuel drain catch cans are installed:
900 Inspect fuel drain catch cans for condition and security. 71−70−00