CSP−900RMM−2MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 221
Revision 36
29-00-00
(4). Inspect reservoir sight glass for cracks,
crazing and discoloration. Replace hand
pump if sight glass is leaking or visual
reference is impaired.
C. Installation
(Ref. Figure 206)
Consumable Materials
(Ref. CSP−SPM)
Item Nomenclature
C112 Hydraulic Fluid
(1). Remove protective caps from end
fittings of tubes (3 and 4) and port
fittings of pump (1).
Hydraulic Fluid (C112)
(2). Install hydraulic hand pump.
(a). Align pump (1) with nutplate holes
on left-hand edge of transmission
deck, just aft of hydraulic system
GSE panel.
(b). Install bolts (5) and washers (6).
Torque bolts.
(c). Lubricate threads of pump port
fittings with clean hydraulic fluid
(C112).
(d). Connect System No. 2 pump fill tube
(4) to lower port fitting of pump (1).
Torque tube fitting.
(e). Connect System No. 1 pump fill tube
(3) to upper port fitting of pump (1).
Torque tube fitting.
(3). Service the hydraulic system (ref.
Section 12-00-00).
(4). Close Access Door L155 (ref. Section
06-00-00).