1.7 Maintenance and Inspection
1.7.1 Check items and cycles
The normal use conditions of the servo are: Annual average ambient temperature: 30
℃
Average
load rate: below 80% Daily operating time: 20 hours or less. The items of daily inspection are as
follows:
Type Inspection cycle Check item
Daily inspection Daily
◆
Check the ambient temperature, humidity, dust, foreign matter, and condensation
◆
Is there any abnormal vibration or noise
◆
Voltage
◆
Peculiar smell
◆
Are there any foreign objects in the vents?
◆
Whether the connector is loose
◆
Whether there is foreign matter between the cable and the connector, and whether the
cable conductor is exposed
◆
Is the fastening part loose?
1.7.2 Replacement of parts
The components inside the servo products will wear and age over time, and the replacement time
of the components varies according to the environmental conditions and usage methods. When
replacement is required, please contact our company or our agent.
Please do not disassemble and repair by yourself.
Part Part Standard replacement cycle Remark
Driver
Filter capacitor About 6 years
The standard replacement cycle is for
reference only. Even if the standard
replacement cycle is not completed, it
needs to be replaced in the event of an
abnormality.
Aluminum electrolytic
capacitors on circuit
boards
About 6 years
Power-up buer relay
About 100,000 times (depending on usage
conditions)
Power-on snubber resistor
About 20,000 times (depending on usage
conditions)
Motor Oil seal 5000 hours