Programming and Adjustment Section 3-3
If the following DM settings are made, the scaling as shown in the following
graph will be performed.
APR Instruction The following is a program example for BCD output data stored in DM 0000
DM 0100
DM 0101
DM 0102
DM 0103
0030
0100
0200
0400
(Hexadecimal) (1) Offset
(BCD) (2) Gain (graph gradient)
(Hexadecimal) (3) (3)/(2)
(Hexadecimal) (4) Upper limit
DM 0104
FC00
(Hexadecimal) (5) Lower limit
Output data (Hexadecimal)
*1
(4) 0400
(+ 5 V)
0230
(1) 0030
100 (2)
0200 (3)
–9999 *2
0100 9999
FC00 (5)
(–5 V)
Value of DM 0000
(Input data)
(BCD)
*1: Output data is hexadecimal.
*2: By executing the STC (40) instruction instead of the CLC (41) instruction, turning the carry
(25504) ON, and executing the SLC3 instruction, the input value of the SLC3 instruction for
DM 0000 will be treated as a negative value.
* "n" indicates the allocated word for analog output 1.
APR
DM0100
DM0000
n
Input condition

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CQM1 and is the answer not in the manual?

Omron CQM1 Specifications

General IconGeneral
ModelCQM1
I/O CapacityUp to 256 I/O points
Programming LanguageLadder Logic
Timer/Counter128 timers/counters
Operating Temperature0 to 55°C
Humidity10 to 90% RH (non-condensing)
Power Supply24 VDC or 100-240 VAC
Communication PortsRS-232C
Memory Capacity3.2K words
Instruction SetBasic and advanced instructions
MemoryRAM (battery-backed)
Program Memory3.2K words
Storage Temperature-20 to 75°C

Related product manuals