148
Mounting and Dismounting the Sensor Module Section 3-2
Mutual Interference When installing two or more sensors face to face or side by side, ensure that
the minimum distances given in the following table are maintained. Sensors
can be mounted together in parallel, however, if their cable length switches
are set to different values.
3-2 Mounting and Dismounting the Sensor Module
Mounting
Mount the E3C-MA11 securely to the Sensor Unit so that the fiber sensor con-
nector side is on the left and the indicator side is on the right.
Dismounting A pulling tool is provided with the Sensor Unit. To dismount the E3C-MA11
from the Sensor Unit, hook the pulling tool onto the square hole on the right
side of the E3C-MA11 and pull out the E3C-MA11 carefully.
Note Be sure to turn off the CQM1-SEN001 before mounting or dismounting sensor
modules.
Model Distance (mm)
AB
E2C-CR5B 20 15
E2C-CR8@ 20 15
E2C-X1A 20 15
E2C-C1A 20 15
E2C-X1R5A 20 15
A
B
Pulling tool