142
Switch Settings Section 2-2
Indicators
Note When the mode selector is set to SET, the operation indicator and stability
operation indicator are used to monitor teaching. Refer to 4-1-1 E3X-MA11
Optical Fiber Photoelectric Module for details.
2-2 Switch Settings
2-2-1 E3X-MA11 Optical Fiber Photoelectric Module
E3C-MA11 Photoelectric Module
Operation Mode Selector
Timer Selector
Name Color Function
OPE Orange Lit when the control output is ON.
STAB Green The stability operation indicator shows the stability
of detecting or non-detecting operations. The sta-
bility operation indicator will be lit when a sensing
object is located 0.93 times as near as the sensing
distance or less. The stability operation indicator
will be also lit when a sensing object is located 1.07
times as far as the sensing distance or more.
Cable length switchesTimer selector
0 ms: No timer
10 ms: OFF-delay timer
Side View
(Refer to 2-2-2 E2C-MA11
Proximity Sensor Module for
details.)
(Refer to 2-2-2 E2C-MA11
Proximity Sensor Module for
details.)
Setting Function
Light• on The control output is ON when there is light incident.
Dark• on The control output is ON when there is no light incident.
Setting Function
0 ms No timer
10 ms 10-ms OFF delay timer active