8-19
high
leakage detection level (i.e., a sensitivity current of 200 mA or greater per Unit, with an operating
time
of 0.1 s or more), or one that incorporates high frequency measures (i.e., one designed for use
with Inverters).
It
will
also help to some extent to lower the Inverter
s carrier frequency (parameter C6-01). In addition,
remember
that the leakage current increases as
the cable is lengthened. (In general, approximately
5 mA of leakage current occurs for each meter of cable.)
H If There is Mechanical Vibration
D The machinery is making unusual sounds.
There
may
be resonance between the mechanical system’
s characteristic frequency and the carrier
frequency.
If the motor is running with no problems and the machinery is vibrating with a high-pitched
whine,
it may
indicate that this is occurring. T
o prevent this type of resonance, adjust the carrier fre
-
quency with parameters C6-01 to C6-03.
There
may be resonance between a machine’
s characteristic frequency and the output frequency of
the Inverter. To prevent this from occurring, either use the jump frequency functions in parameters
d3-01 to d3-04 or install rubber padding on the motor base to reduce vibration.
D Vibration and hunting are occurring with open-loop vector control.
The
gain adjustment may be insuf
ficient. Reset the gain to a more ef
fective level by adjusting parame
-
ters C4-02 (torque compensation time constant), C8-08 (AFR gain), and C3-02 (slip compensation
primary delay time) in order. Lower the gain setting and raise the primary delay time setting.
D Vibration and hunting are occurring with V/f control.
The
gain adjustment may be insuf
ficient. Reset the gain to a more ef
fective level by adjusting parame
-
ters C4-02 (torque compensation time constant), C7-02 (hunting prevention gain), and C3-02 (slip
compensation primary delay time) in order. Lower the gain setting and raise the primary delay time
setting.
D Vibration and hunting are occurring with flux vector control.
The
gain adjustment may be insuf
ficient. Adjust the various types of speed control loop (ASR) gain.
(For
details, refer to
Chapter
5 Basic Operation
of this manual.) If the mechanical system’
s resonance
point
coincides with the Inverter
s operating frequency and the vibration cannot be eliminated in this
way, increase the ASR primary delay time (parameter C5-06)
and then try adjusting the gain again.
D Vibration and hunting are occurring with V/f w/PG control.
The
gain adjustment may be insuf
ficient. Adjust the various types of speed control loop (ASR) gain.
(For
details, refer
to
Chapter
5 Basic Operation
of this manual.) If the vibration cannot be eliminated in
this
way
, set
the hunting prevention selection (parameter C7-01) to “0” (disabled) and then try adjust
-
ing the gain again.
D Vibration and hunting are occurring with PID control.
Check the vibration cycle and individually adjust the P, I, and D. (Refer to page 6-55.)
Maintenance Operations Chapter
8