D New Parameter Default Setting
Parameter
number
Parameter name Applicable
Inverters
Previous setting
range
New setting
range
L2-04 Voltage restart time Inverters of
55 kW or larger
0.6 s 1.0 s
1-3-4 Software
V
er. VSG101114
H PG Speed Deviation Detection Function Upgrade (F1-04)
This
function has been changed so that the conditions can be selected for speed deviation (DEV) detec
-
tion. Either of the following two conditions can be selected by means of an F1-04 parameter setting.
D Detect only when the frequency reference matches the output frequency (within the range set in
L4-02).
D Detect only when the frequency reference matches the PG feedback speed (within the range set
in L4-02).