 Operation Using the Digital Operator
• Press the Run Key. The motor will start to rotate. (forward rotation)
• Press the Forward/Reverse Key. The motor will rotate in the reverse direction.
• Press
the Stop Key
. The motor will stop. (The operation LED indicator will keep flashing until the motor
stops.)
• The frequency reference can be changed, even during operation. When this is done, the frequency
reference is changed as soon as the Enter Key is pressed to input the set values.
• If
the Jog Key is pressed when the Unit is
stopped, it will rotate by the jog frequency (default setting: 6.0
Hz) only while the Key is being pressed.
 Checking the Operating Status
• After changing the frequency reference or the rotation direction, check that there is no vibration or
abnormal sound from the motor.
• Check that no faults have occurred in the Inverter during operation.
4-2-7 Actual Load Operation
• After checking the operation with the motor in no-load status, connect the mechanical system and
operate with an actual load.
 Connecting the System
• After confirming that the motor has stopped completely, connect the mechanical system.
• Be sure to tighten all the screws when fixing the motor axis in the mechanical system.
 Operation using the Digital Operator
• In
case a fault occurs during
operation, make sure the Stop Key on the Digital Operator is easily acces
-
sible.
• Use the Digital Operator in the same way as no-load operation.
• First set the frequency reference to a low speed of one tenth the normal operating speed.
 Checking Operating Status
• Having
checked that the operating direction is correct and that the machine is operating smoothly at
slow speed, increase the frequency reference.
• After changing the frequency reference or the rotation direction, check that there is no vibration or
abnormal
sound from the motor
. Check the monitor display to ensure that the U1-03 (output current) is
not becoming excessive.
Trial Operation Chapter
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3FV and is the answer not in the manual?

Omron SYSDRIVE 3G3FV Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3FV
CategoryInverter
LanguageEnglish

Related product manuals