7-35
Para
meter
No.
PageControl
mode
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
DescriptionNamePara
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
F9-06
Operation
after
communica
tions error
Selects the inverter operation to
perform when a
communications (CompoBus/D
Communications Card) error
occurs.
0:
Decelerate to stop in the
time set in C1-02.
(Protective operation)
1:
Coast to sto
p
0 to 3
1 NO B B B B 6-75
BUS Fault
Sel
1:
C
oast to stop.
(Protective operation)
2:
Emergency stop in the time
set in C1-09.
(Protective operation)
3:
Continue operation.
(Alarm)
7-2-6 Terminal Parameter Lists
H Digital Inputs: H1
Parame-
ter No
Name
Description Setting
range
Default
setting
Chan-
ges
Control mode
Page
ter No.
Display
name
range setting ges
during
opera-
tion
V/f con
-
trol
V/f with
PG
Open
loop
vector
Flux
vector
H1-01 Multi-func-
tion input 1:
T
erminal 3
selection
T
erminal 3 Sel
0 to 77
24 NO B B B B 6-78
H1-02 Multi-func-
tion input 2:
T
erminal 4
selection
T
erminal 4 Sel
0 to 77
14 NO B B B B 6-78
H1-03 Multi-func-
tion input 3:
T
erminal 5
selection
T
erminal 5 Sel
0 to 77
3 (0)
(See
note.)
NO B B B B 6-78
H1-04 Multi-func-
tion input 4:
T
erminal 6
selection
T
erminal 6 Sel
0 to 77
4 (3)
(See
note.)
NO B B B B 6-78
H1-05 Multi-func-
tion input 5:
T
erminal 7
selection
T
erminal 7 Sel
0 to 77
6 (4)
(See
note.)
NO B B B B 6-78
H1-06 Multi-func-
tion input 6:
T
erminal 8
selection
T
erminal 8 Sel
0 to 77
8 (6)
(See
note.)
NO B B B B 6-78
Note The values in parentheses indicate initial values when initialized in 3-wire sequence.
D Digital Input Functions List
Setting
l
Function
Control mode
Page
g
value
V/f V/f
w/PG
Open loop
Vector
Flux
vector
g
0 3-wire control (Forward/Reverse command) OK OK OK OK 5-16
1 Local/Remote selection (ON: Operating, OFF:
Setting parameters)
OK OK OK OK 6-79
Parameter Lists Chapter
7

Table of Contents