7-34
Para
meter
No.
PageControl
mode
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
DescriptionNamePara
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
F8-01
E-15
operation
selection
Selects inverter operation to
perform when a
communications error occurs at
the SYSMAC BUS (Wired) I/F
Card.
0 to 3
1 NO B B B B 6-74
E-15 Det
Sel
.
0:
Decelerate to stop.
1:
Coast to stop.
2:
Emergency stop.
3:
Continue operation.
F9-01
Commu-
nications
external
fault input:
input type
Selects the type of input used
for the communications external
fault input from communications
(CompoBus/D Communications
Card.)
0, 1
0 NO B B B B 6-74
EFO
Selection
0:
Normally open input
1:
Normally closed input
F9-02
Commu-
nications
external
fault input:
detection
method
Selects the detection method for
used for the communications
external fault input from
communications (CompoBus/D
Communications Card.)
0: Always detect.
0, 1
0 NO B B B B 6-74
EFO
Detection
1:
Detect during operation.
F9-03
Commu-
nications
external
fault input:
Operation
Selects the inverter operation to
perform when there is an
communications external fault
input from communications
(CompoBus/D Communications
Card.)
0:
Decelerate to stop in the
time set in C1-02.
(Protective operation)
p
0 to 3
1 NO B B B B 6-75
EFO Fault
Action
1:
Coast to stop.
(Protective operation)
2:
Emergency stop in the time
set in C1-09.
(Protective operation)
3:
Continue operation.
(Alarm)
F9-04
Not used.
---
0 to
F9-05
Torque
reference/
torque limit
selection
from
communica
tions
This setting enables or disables
torque reference and torque
limit values input from
communications (CompoBus/D
Communications Card.)
Note: Always set to “disable”
when using a CompoBus/
D Communications Card.
0:
Disable torque reference/
0, 1
1 NO X X X B 6-75
TorqueRef/
Lmt Sel
torque limit from
communications.
1:
Enable torque reference/
torque limit from
communications.
Parameter Lists Chapter