3-18
3-4 Initialize Mode
The
initialize mode
is used to select the language displayed by the Unit, the access level,
and the control mode; it is also used to initialize the Unit’s parameters.
S Selecting the Display Language
Use parameter A1-00 to select the language displayed by the Unit. Messages can be displayed in
0:
English,
1: Japanese, 2: German, 3: French, 4: Italian, 5: Spanish, or 6: Portuguese. This parameter is
not initialized by the initialize operation and it can be changed during operation.
Note The language that is set will be indicated on the display.
Parameter Display name Setting Units Default
Valid access levels
number
range setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
A1-00 Select Language 0 to 6 --- 0 Quick-start, Basic, or Advanced
Example
The
following example shows how to change parameter A1-00 so that Japanese is
displayed instead of
English.
Key sequence Display Explanation
** Main Menu **
Operation
Displays operation mode.
** Main Menu **
Initialize
Displays initialize mode.
Select Language
English
Puts the Unit in initialize mode.
(Select Language display)
A1-00= 0
English
Displays the parameter setting for A1-00.
A1-00= 1 ***
FN]:^
Sets the display language to Japanese.
<^.3=3 67:P6] Writes the new setting.
9^]:^ >]@8
FN]:^
Returns to the Select Language display.
S Setting the Access Level
Use parameter A1-01 to select the parameter access level. This level determines which parameters
can be displayed and changed. (The parameters which can be displayed and changed also depend
upon the control mode being used.) This parameter can be changed during operation.
Parameter Display name Setting Units Default
Valid access levels
number
range setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
A1-01 Access Level 0 to 4 --- 2 Quick-start, Basic, or Advanced
Preparing for Operation Chapter
3