EasyManuals Logo

Omron SYSDRIVE 3G3FV User Manual

Omron SYSDRIVE 3G3FV
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
1-11
1-3 New Functions
The following software versions have been implemented for the 3G3FV Series to add
and upgrade functions.
August 1996: Software Ver. VSG101032 (S1032)
April 1997: Software Ver. VSG101040 (S1040)
Sept. 1998: Software Ver. VSG101043 (S1043)
Sept. 1999: Software Ver. VSG101113 (S1113)
Sept. 2000: Software Ver. VSG101114 (S1114)
The
software version
can be confirmed using the 5-digit number display for the FLASH
ID for U1-14.
This
section describes the new functions and improvements for
each software version.
Refer to
Chapter 5 Basic Operation
and
Chapter 6 Advance Operation
.
1-3-1 Software
V
er. VSG101040
H CompoBus/D (DeviceNet) Communications Card
The
CompoBus/D Communications Card can be used to connect the
Inverter to a DeviceNet network.
The following function additions and improvements were made to support this new functionality.
D CompoBus/D Addition to the Frequency Reference Selection (Parameter b1-01)
A
function was added to Frequency Reference Selection so that the Inverter frequency reference can
be input via DeviceNet communications.
D CompoBus/D Addition to the Run Source Selection (Parameter b1-02)
A
function was added to Run Source Selection so that the Inverter run command can be input via Devi
-
ceNet communications.
D Communications External Fault Input (Parameters F9-01 to F9-03)
A function was added to support an external fault input from DeviceNet communications to stop the
Inverter
when
an error occurs. Sequence settings and operation designation for errors for the commu
-
nications external fault input have been added.
H Two-motor Switching Control
A
function was added to enable switching control between two motors using one Inverter
. The following
function additions were made to support this new functionality.
D Control Mode Setting Second Motor (Parameter E3-01)
A control mode setting was added so that the second motor can be set to a different mode.
Note The
control mode setting was limited to 0 (
V/f
control without PG) or 2 (open-loop vector control), but
was changed in system version VSG101043 to support all control modes 0 to 3.
D V/f Pattern Settings for Second Motor (Parameters E4-01 to E4-06)
V/f pattern settings were added so that the second motor can be set to a different pattern.
Introduction Chapter
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3FV and is the answer not in the manual?

Omron SYSDRIVE 3G3FV Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3FV
CategoryInverter
LanguageEnglish

Related product manuals