1-11
1-3 New Functions
The following software versions have been implemented for the 3G3FV Series to add
and upgrade functions.
August 1996: Software Ver. VSG101032 (S1032)
April 1997: Software Ver. VSG101040 (S1040)
Sept. 1998: Software Ver. VSG101043 (S1043)
Sept. 1999: Software Ver. VSG101113 (S1113)
Sept. 2000: Software Ver. VSG101114 (S1114)
The
software version
can be confirmed using the 5-digit number display for the FLASH
ID for U1-14.
This
section describes the new functions and improvements for
each software version.
Refer to
Chapter 5 Basic Operation
and
Chapter 6 Advance Operation
.
1-3-1 Software
V
er. VSG101040
H CompoBus/D (DeviceNet) Communications Card
The
CompoBus/D Communications Card can be used to connect the
Inverter to a DeviceNet network.
The following function additions and improvements were made to support this new functionality.
D CompoBus/D Addition to the Frequency Reference Selection (Parameter b1-01)
A
function was added to Frequency Reference Selection so that the Inverter frequency reference can
be input via DeviceNet communications.
D CompoBus/D Addition to the Run Source Selection (Parameter b1-02)
A
function was added to Run Source Selection so that the Inverter run command can be input via Devi
-
ceNet communications.
D Communications External Fault Input (Parameters F9-01 to F9-03)
A function was added to support an external fault input from DeviceNet communications to stop the
Inverter
when
an error occurs. Sequence settings and operation designation for errors for the commu
-
nications external fault input have been added.
H Two-motor Switching Control
A
function was added to enable switching control between two motors using one Inverter
. The following
function additions were made to support this new functionality.
D Control Mode Setting Second Motor (Parameter E3-01)
A control mode setting was added so that the second motor can be set to a different mode.
Note The
control mode setting was limited to 0 (
V/f
control without PG) or 2 (open-loop vector control), but
was changed in system version VSG101043 to support all control modes 0 to 3.
D V/f Pattern Settings for Second Motor (Parameters E4-01 to E4-06)
V/f pattern settings were added so that the second motor can be set to a different pattern.
Introduction Chapter
1