10-9
Param-
eter
No.
Ref-
er-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of
set-
ting
Set-
ting
range
DescriptionNameRegis-
ter No.
(Hex)
n041 0129 Acceleration
time 3
Acceleration time: The time it takes
maximum frequency to go from 0% to
100%.
0.0 to
6,000
0.1 s
(May
be
h
10.0 Yes p5-25
n042 012A Deceleration
time 3
100%
.
Deceleration time: The time it takes
maximum frequency to go from 100%
to 0%
chang
ed at
n018.)
10.0 Yes p5-25
n043 012B Acceleration
time 4
t
o
0%
.
* Actual acceleration/deceleration
time is calculated using the follow-
if lA l i/d l
10.0 Yes p5-25
n044 012C Deceleration
time 4
g
ing formula. Acceleration/decelera-
tion time setting x frequency refer-
ence/maximum frequency
10.0 Yes p5-25
List of Parameters Chapter 10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV SERIES and is the answer not in the manual?

Omron SYSDRIVE 3G3MV SERIES Specifications

General IconGeneral
ModelSYSDRIVE 3G3MV SERIES
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1 to 400 Hz
Cooling MethodForced Air Cooling
Input Voltage200 to 240 VAC, 380 to 480 VAC
Horsepower Range0.1 to 15 HP
Power Range0.1 to 11 kW
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5 to 95% RH (non-condensing)
Vibration5.9 m/s² or less
Voltage Class200V, 400V