10-10
H Function Group 2 (n050 through n079)
Para
me-
ter
No.
Reg-
ister
No.
(Hex)
Name Description Set-
ting
range
Unit
of
set-
ting
Default
setting
Chan-
ges dur-
ing
opera-
tion
Ref-
er-
ence
page
n050 0132 Multi-func-
tion input 1
-
Used to select the functions of multi-function
input terminals S1 through S7.
1 to
33
1 1 No 5-30
npu
er-
minal S1)
Set
value
Function Description
See
note.)
n051 0133 Multi-func-
tion input 2
(Input ter-
minal S2)
0 Forward/
Reverse
rotation
command
3-wire sequence (to
be set in n052 only)
By setting to 0, the set
values in n050 and
n051 are ignored and
the following settings
are forcibly made.
1 to
33
(26
See
note.)
1 2 No 5-30
n052 0134 Multi-func-
tion input 3
(Input ter-
minal S3)
S1: RUN input (RUN
when ON)
S2: STOP input
(STOP when OFF)
S3: Forward/Reverse
rotation command
(OFF: Forward; ON:
Reverse)
0 to
33
(26
See
note.)
1 3 No 5-30
n053 0135 Multi-func-
tion input 4
(Input ter-
minal S4)
1 Forward/
Stop
Forward rotation com-
mand in 2-wire
sequence. (Forward
rotation with the signal
turned ON)
1 to
33
(26
See
note.)
1 5 No 5-30
n054 0136 Multi-func-
tion input 5
(Input ter-
minal S5)
2 Reverse/
Stop
Reverse rotation com-
mand in 2-wire
sequence (Reversed
with the terminal
turned ON)
1 to
33
(26
See
note.)
1 6 No 5-30
n055 0137 Multi-func-
tion input 6
(Input ter-
3 External
fault (NO)
ON: External fault
(EFj detection: j is
a terminal number)
1 to
33
(26
1 7 No 5-30
minal S6)
4 External
fault (NC)
OFF: External fault
(EFj detection: j is
a terminal number)
See
note.)
n056 0138 Multi-func-
tion input 7
(Input ter-
minal S7)
5 Fault reset ON: Fault reset (dis-
abled while RUN com-
mand is input)
1 to
35,
(26
See
note.)
1 10 No 5-30
Note Inverter overheating warning (setting value: 26) can be set for 5.5-kW and 7.5-kW Inverters only.
List of Parameters Chapter 10