10-15
Para
me-
ter
No.
Reg-
ister
No.
(Hex)
Name Description Set-
ting
range
Unit
of
set-
ting
Defaul
t set-
ting
Chan-
ges dur-
ing
opera-
tion
Ref-
er-
ence
page
n057 0139 Multi-func-
tion output
Used to select the functions of multi-function
output terminals.
0 to 7,
10 to
1 0 No 5-36
1 (MA/MB
and MC
Set
value
Function Description
19
(21
output ter-
minals)
0 Fault output ON: Fault output (with
protective function
working)
See
note.)
n058 013A Multi-func-
tion output
1 During
RUN
ON: During RUN
0 to 7,
10 to
1 1 No 5-36
2 (P1-PC
output ter-
minals)
2 Frequency
agree
ON: Output frequency
agree with frequency
reference
19
(21
See
3 Zero speed ON: Zero speed (at
less than min. output
frequency)
note.
n059 013B Multi-func-
tion output
3 (P2-PC
4 Frequency
detection 1
ON: Output frequency
y frequency detection
level (n095)
0 to 7,
10 to
19
1 2 No 5-36
output ter-
minals)
5 Frequency
detection 2
ON: Output frequency
x frequency detection
level (n095)
(21
See
note.)
6 Overtorque
being moni-
tored (NO-
contact out-
put)
Output if any of the fol-
lowing parameter
conditions is satisfied.
n096: Overtorque
detection function
selection 1
n097: Overtorque
detection function
selection 2
7 Overtorque
being moni-
tored (NC-
contact out-
put)
n098: Overtorque
detection level
n099: Overtorque
detection time
NO contact: ON with
overtorque being
detected
NC contact: OFF with
overtorque being
detected
Note Frequency reference loss (setting value: 20) and inverter overheating warning (setting value: 21)
can be set for 5.5-kW and 7.5-kW Inverters only.
List of Parameters Chapter 10