EasyManuals Logo

Omron SYSDRIVE 3G3MV SERIES User Manual

Omron SYSDRIVE 3G3MV SERIES
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
3-12
7. Check that the data is written correctly with the item vFy selected.
The above procedure is possible provided that the Inverters have the same power supply specification
and control mode (i.e., V/f or vector control). It is not possible to copy parameters from a 200-V model
to a 400-V model or from an Inverter that is in V/f control mode to another that is in vector control mode,
for example.
Note 1. The following parameter set values or output frequency on hold cannot be copied.
n176: Parameter copy function selection
n177: Parameter read-prohibit selection
n178: Error log
n179: Software version
Note 2. The following parameter set values cannot be copied if the Inverters are different to each
other in capacity.
n011 to n017: V/f setting
n036: Rated motor current
n080: Carrier frequency
n105: Torque compensation core loss
n106: Rated motor slip
n107: Motor wire-to-wire resistance
n108: Motor leakage inductance
n109: Torque compensation limit
n110: Motor no-load current
n140: Energy-saving control coefficient K2
n158: Motor code
Note 3. Functions for 5.5-/7.5-kW Inverters cannot be copied to Inverters with different capacities.
H Setting n001 for Parameter Write-prohibit Selection/Parameter
Initialization
No data can be written to n176 for parameter copy function selection unless the default setting is
changed. To write data to this parameter, set n001 for parameter write-prohibit selection/parameter
initialization to 4.
Preparing for Operation and Monitoring Chapter 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV SERIES and is the answer not in the manual?

Omron SYSDRIVE 3G3MV SERIES Specifications

General IconGeneral
ModelSYSDRIVE 3G3MV SERIES
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1 to 400 Hz
Cooling MethodForced Air Cooling
Input Voltage200 to 240 VAC, 380 to 480 VAC
Horsepower Range0.1 to 15 HP
Power Range0.1 to 11 kW
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5 to 95% RH (non-condensing)
Vibration5.9 m/s² or less
Voltage Class200V, 400V