No. Name
User
Setting
L4-02 Speed Agreement Detection Width
L4-03 Speed Agreement Detection Level (+/-)
L4-04 Speed Agreement Detection Width (+/-)
L4-05
Frequency Reference Loss Detection
Selection
L4-06 Frequency Reference at Reference Loss
L4-07 Frequency Detection Conditions
L5-01 Number of Auto Restart Attempts
L5-02 Auto Restart Operation Selection
L5-04 Fault Reset Interval Time
L5-05 Fault Reset Operation Selection
L6-01 Torque Detection Selection 1
L6-02 Torque Detection Level 1
L6-03 Torque Detection Time 1
L6-04 Torque Detection Selection 2
L6-05 Torque Detection Level 2
L6-06 Torque Detection Time 2
L6-08 Mechanical Weakening Detection Operation
L6-09
Mechanical Weakening Detection Speed
Level
L6-10 Mechanical Weakening Detection Time
L6-11 Mechanical Weakening Detection Start Time
L7-01 Forward Torque Limit
L7-02 Reverse Torque Limit
L7-03 Forward Regenerative Torque Limit
L7-04 Reverse Regenerative Torque Limit
L7-06 Torque Limit Integral Time Constant
L7-07
Torque Limit Control Method Selection
during Accel/Decel
L8-01
Internal Dynamic Braking Resistor Protection
Selection (ERF type)
L8-02 Overheat Alarm Level
L8-03 Overheat Pre-Alarm Operation Selection
L8-05 Input Phase Loss Protection Selection
L8-07 Output Phase Loss Protection
L8-09 Output Ground Fault Detection Selection
L8-10 Heatsink Cooling Fan Operation Selection
L8-11 Heatsink Cooling Fan Operation Delay Time
L8-12 Ambient Temperature Setting
L8-15 oL2 Characteristics Selection at Low Speeds
L8-18 Soft CLA Selection
L8-19
Frequency Reduction Rate during oH
Pre-Alarm
L8-29 Current Unbalance Detection (LF2)
L8-35 Side-by-Side Selection
L8-38 Carrier Frequency Reduction
L8-41 Current Alarm Selection
n1-01 Hunting Prevention Selection
n1-02 Hunting Prevention Gain Setting
n1-03 Hunting Prevention Time Constant
n1-05 Hunting Prevention Gain while in Reverse
n2-01
Speed Feedback Detection Control (AFR)
Gain
n2-02
Speed Feedback Detection Control (AFR)
Time Constant
n2-03
Speed Feedback Detection Control (AFR)
Time Constant 2
n3-01
High-Slip Braking Deceleration Frequency
Width
n3-02 High-Slip Braking Current Limit
n3-03 High-Slip Braking Dwell Time at Stop
n3-04 High-Slip Braking Overload Time
n3-13 Overexcitation Deceleration Gain
n3-21 High-Slip Suppression Current Level
n3-23 Overexcitation Operation Selection
n6-01 Line-to-Line Motor Resistance Online Tuning
n8-45 Speed Feedback Detection Control Gain
n8-47 Pull-In Current Compensation Time Constant
n8-48 Pull-In Current
n8-49 Load Current
n8-51 Acceleration Time Pull-In Current
n8-54 Voltage Error Compensation Time Constant
n8-55 Load Inertia
n8-62 Output Voltage Limit
o1-01 Drive Mode Unit Monitor Selection
o1-02 User Monitor Selection After Power Up
o1-03 Digital Operator Display Selection
o1-10
Frequency Reference Setting and User-Set
Display
o1-11
Frequency Reference Setting/Decimal
Display
o2-01 LOCAL/REMOTE Key Function Selection
o2-02 STOP Key Function Selection
o2-03 User Parameter Default Value
o2-04 Drive/kVA Selection
o2-05
Frequency Reference Setting Method
Selection
o2-06
Operation Selection when Digital Operator is
Disconnected
o2-07
Motor Direction at Power Up when Using
Operator
o2–09 Initialization Mode
o4-01 Accumulated Operation Time Setting
o4-02 Accumulated Operation Time Selection
o4-03
Cooling Fan Maintenance Setting (Operation
Time)
o4-05 Capacitor Maintenance Setting
o4-07 Inrush Prevention Relay Maintenance Setting
o4-09 IGBT Maintenance Setting
o4-11 U2, U3 Initial Value Selection
o4-12 kWh Monitor Initial Value Selection
o4-13 Motor r/min Reset
r1-01 FDBs Connection Parameter 1 (upr.)
r1-02 FDBs Connection Parameter 1 (lwr.)
r1-03 FDBs Connection Parameter 2 (upr.)
r1-04 FDBs Connection Parameter 2 (lwr.)
r1-05 FDBs Connection Parameter 3 (upr.)
r1-06 FDBs Connection Parameter 3 (lwr.)
r1-07 FDBs Connection Parameter 4 (upr.)
r1-08 FDBs Connection Parameter 4 (lwr.)
r1-09 FDBs Connection Parameter 5 (upr.)
r1-10 FDBs Connection Parameter 5 (lwr.)
r1-11 FDBs Connection Parameter 6 (upr.)
r1-12 FDBs Connection Parameter 6 (lwr.)
r1-13 FDBs Connection Parameter 7 (upr.)
r1-14 FDBs Connection Parameter 7 (lwr.)
r1-15 FDBs Connection Parameter 8 (upr.)
r1-16 FDBs Connection Parameter 8 (lwr.)
r1-17 FDBs Connection Parameter 9 (upr.)
r1-18 FDBs Connection Parameter 9 (lwr.)
r1-19 FDBs Connection Parameter 10 (upr.)
r1-20 FDBs Connection Parameter 10 (lwr.)
r1-21 FDBs Connection Parameter 11 (upr.)
r1-22 FDBs Connection Parameter 11 (lwr.)
r1-23 FDBs Connection Parameter 12 (upr.)
r1-24 FDBs Connection Parameter 12 (lwr.)
r1-25 FDBs Connection Parameter 13 (upr.)
D.5 User Setting Table