EVO Installation Guide 119
C.0.63 Confidential Mode Timer
Section [012]
Section [012] determines the amount of time without action before the keypad enters Confidential Mode. The
Confidential Mode Timer can be set from 005 seconds to 255 seconds. Default: 120 seconds
C.0.64 Muting
Section [009] Option [3]
Option [3] OFF = Audible sounds (default).
Option [3] ON = Mute.
C.0.65 Beep on Exit Delay
Section [009] Option [4]
Option [4] OFF = Exit Delay beep disabled.
Option [4] ON = Exit Delay beep enabled (default).
C.0.66 Chime on Zone Closure
Section [009] Option [5]
Option [5] OFF = Chime on Zone Closure disabled (default).
Option [5] ON = Chime on Zone Closure enabled.
C.0.67 Beep on Trouble
Section [010] Options [1] To [4]
System Troubles / Clock Loss
Option [1] OFF = Disabled (default).
Option [1] ON = Enabled.
Communicator Troubles
Option [2] OFF = Disabled (default).
Option [2] ON = Enabled.
Module / Communication Bus Troubles
Option [3] OFF = Disabled (default).
Option [3] ON = Enabled.
Zone Troubles
Option [4] OFF = Disabled (default).
Option [4] ON = Enabled.
C.0.68 Keypad Anti-tamper Enable
Section [011] Option [5]
Option [5] OFF = Keypad's anti-tamper is disabled (default).
Option [5] ON = Keypad's anti-tamper is enabled.