PTX_SETUP commands have the following format:
(SFCC)PTX_SETUP
Command–Sub Command;Value
PTX_END
For example, if the SFCC assigned to PTX_SETUP is the default value of the
exclamation mark (!, hex 21),
and you wanted to load configuration number 4
and capture all incoming data to a file named “BIN”, you
would use the
following command:
!PTX_SETUP
CONFIG–LOAD;4 FILE_IO–CAPTURE;BIN
PTX_END
Table 27 lists all the command, sub-command, and parameter combinations
and gives a brief description
of the command. This section documents the
existence of PTX_SETUP commands which work across all
platforms. The
following sections document commands which are specific to thermal.
NOTE: When a file system error occurs, a message will be displayed on the
front panel indicating the
error, and the action needed to take to
correct the error.
Cfg can be 0-8. The PTX_SETUP
will load configuration Cfg. If
configuration Cfg was not previously
saved, the operator panel will
display an error message and the
current configuration will be kept.
Cfg must be 1-8. This command will
save the current configuration as
configuration Cfg. If Cfg is not in the
range of 1-8, the command is
ignored.
Menu_tag is the name of the menu
as defined in the menu file. Value is
the value to which the menu is to be
set.
Sets the power-up configuration to
Cfg and loads Configuration Cfg.
Cfg can be any value from 0-8,
where 0 is the factory default.