Fax Unit B404
BIT SWITCHES
SM 5-21 B404
System Switch 1E
No FUNCTION COMMENTS
5 Address display priority in the
AI redial mode.
0: RTI/CSI
1: Telephone number
0: When the machine has both RTI/CSI and the
telephone number information, the machine displays
RTI/CSI.
1: The machine always displays the telephone
number.
6-7 Not used Do not change the settings.
System Switch 1F
No FUNCTION COMMENTS
0 Not used Do not change the settings.
1 Report printout after an original
jam during SAF storage or if
the SAF memory fills up
0: Enabled
1: Disabled
0: When an original jams, or the SAF memory
overflows during scanning, a report will be printed.
Change this bit to “1” if the customer does not want
to have a report in these cases.
Memory tx – Memory storage report
Parallel memory tx – Transmission result report
2 Not used Do not change the settings.
3 Received fax print start timing
(G3 reception)
0: After receiving each page
1: After receiving all pages
0: The machine prints each page immediately after
the machine receives it.
1: The machine prints the complete message after
the machine receives all the pages in the memory.
4-6 Not used Do not change the factory settings.
7 Action when a fax SC has
occurred
0: Automatic reset
1: SC code display
0: When the fax unit detects a fax SC code other
than SC1201, the fax unit automatically resets itself.
1: When the fax unit detects any fax SC code, the
fax unit displays the SC code and stops.
Cross Reference
Fax SC codes - See “Troubleshooting”