Fax Unit B404
SERVICE RAM ADDRESSES
SM 5-65 B404
6800D3(H) - User parameter switch 19 (SWUSR_13)
Bits 0 to 2: Not used
Bit 3: 90° image rotation during B5 portrait Tx
(This switch is not printed on the user parameter list.)
0: Off, 1: On
Bit 4: Reduction of sample images on reports to 50% in the main scan and sub-
scan directions. (This switch is not printed on the user parameter list.)
0: Off, 1: On
Bit 5: Use of A5 size paper for reports
(This switch is not printed on the user parameter list.)
0: Off, 1: On
Bits 6 and 7: Not used
6800D4(H) to 6800D8 - User parameter switch 20 to 24 (SWUSR_14 to 18)
Bits 0 to 7: Not used
6800D9(H) - User parameter switch 25 (SWUSR_19)
Bits 0 to 3: Not used
Bit 4: RDS operation 0: Not acceptable
1: Acceptable for the limit specified by system switch 03
Note: This bit is only effective when RDS operation can be selected by the user.
Bits 5 and 6: Not used
Bit 7: Daylight saving time 0: Disabled, 1: Enabled
6800DA(H) - User parameter switch 26 (SWUSR_1A)
(This switch is not printed on the user parameter list.)
Bit 0: Not used
Bit 1: Dialing type 0: Pulse dialing (10 pps), 1: Tone (DTMF) dialing
Bits 2 to 7: Not used
6800DB(H) - User parameter switch 27 (SWUSR_1B)
PSTN access code from behind a PABX
(This switch is not printed on the user parameter list.)
Access number Hex value to program (BCD)
0F0
""
0F0
00 00
""
99 99
6800DC(H) to 6800DF - User parameter switch 28 to 31 (SWUSR_1C to 1F)
Bits 0 to 7: Not used
680110 to 68011E(H) - Service station’s fax number (Service mode 13)