Anti-condensation Heater (Optional Unit)
D117/D118 2-76 SM
8. Remove the left cover [B] of the mainframe ( x 2).
1: Front right
2: Left
3: Rear
9. Join the mainframe with the optional paper feed unit with four joint brackets [A] (front right),
[B] (front left) and [C] (rear) (x 2). These brackets are secured with the following screws.
[A]: M3 x 12 (included in this kit)
[B]: M3 x 6 (included in this kit)
[C] (Upper): Existing screws (x 2)
[C] (Lower): M3 x 6 (included in this kit)
10. Reassemble the mainframe and the paper feed unit.