Main SP Tables-2
D117/D118 3-74 SM Appendix
004 Ye *ENG
2105
[LD Power Adj.]
Adjusts the LD power of each color for each process speed.
Each LD power setting is decided by process control.
001 High Speed: Bk *ENG
[50.0 to 120.0 / 100.0 / 0.1%/step]
002 High Speed: Ma *ENG
003 High Speed: Cy *ENG
004 High Speed: Ye *ENG
009 Low Speed: Bk *ENG
010 Low Speed: Ma *ENG
011 Low Speed: Cy *ENG
012 Low Speed: Ye *ENG
2106
[Polygon Rotation Time]
Adjusts the time of the polygon motor rotation.
001 Warming-Up *ENG [0 to 60 / 10 / 1sec/step]
002 Job End *ENG [0 to 60 / 0 / 1/step]
2107
[Image Parameter]
Adjusts image parameters.
001 Image Gamma Flag *ENG [0 or 1 / 1 / 1/step]
002 Shading Correction Flag *ENG [0 or 1 / 1 / 1/step]