Main SP Tables-2
D117/D118 3-96 SM Appendix
2221
[LD Power: fixed]
These SP codes set the LD power level for each laser unit.
001 Standard Speed: Bk *ENG
[0 to 200 / 100 / 1%/step]
Increasing this value makes the
image density darker.
002 Standard Speed: C *ENG
003 Standard Speed: M *ENG
004 Standard Speed: Y *ENG
009 Refresh Threshold:Bk *ENG
010 Refresh Threshold:Col *ENG
011 - *ENG
012 - *ENG
2229
[Develop DC Vias]
Adjusts the development vias.
001 Standard Speed: Bk *ENG
[0 to 800 / 450 / 1-V/step]
002 Standard Speed: C *ENG
003 Standard Speed: M *ENG
004 Standard Speed: Y *ENG
009 Low Speed: Bk *ENG
010 Low Speed: C *ENG
011 Low Speed: M *ENG
012 Low Speed: Y *ENG