Main SP Tables-3
D117/D118 3-212 SM Appendix
001 Max Supply Rate:K *ENG
Sets the maximum toner supply rate.
[0 to 100 / 100 / 1%/step]
002 Max Supply Rate:C *ENG
003 Max Supply Rate:M *ENG
004 Max Supply Rate:Y *ENG
011 Min Supply Time: K *ENG
Sets the minimum toner supply rate.
[0 to 255 / 100 / 1msec/step]
012 Min Supply Time: C *ENG
013 Min Supply Time: M *ENG
014 Min Supply Time: Y *ENG
3432 [DrvTime: Setting]
001 DriveTime(max) *ENG
Sets the maximum continuous supply
time.
[0 to 1500 / 800 / 1msec/step]
3440 [Fixed Supply Mode]
001 Fixed Rate: K *ENG
Sets toner supply ratio for fixed supply
mode.
[0 to 100 / 10 / 1%/step]
002 Fixed Rate: C *ENG
003 Fixed Rate: M *ENG
004 Fixed Rate: Y *ENG
3450 [Toner Supply PID: Setting]
001 Vt Proportion: K *ENG
Sets supply coefficient to supply toner
proportionate to Vt-Vtref at toner supply
control.
[0 to 2550 / 40 / 1/step]
002 Vt Proportion: C *ENG
003 Vt Proportion: M *ENG
004 Vt Proportion: Y *ENG
011 Pixel Proportion: K *ENG Sets supply coefficient to supply toner