Main SP Tables-5
D117/D118 3-300 SM Appendix
004
end data set *CTL
[0 to 0xffffffff / - / 1hex/step]
(Default)
NA: 0x11100200
EUR: 0x10500100
ASIA: 0x03100000
Other: 0x00000000
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5401 [Access Control]
103 Default Document ACL *CTL
[0 to 3 / 0 / 1/step]
0: Read Only
1: Edit
2: Edit/Delete
3: Full control
104 Authentication Time *CTL [0 to 255 / 0 / 1sec/step]
162 ExtAuth Detail *CTL [ - / 0x00 / 0x01/step]
200 SDK1 UniqueID *CTL [0 to 0xffffffff / 0 / 1/step]
201 SDK1 Certification Method *CTL [0 to 0xff / 0 / 1/step]
210 SDK2 UniqueID *CTL [0 to 0xffffffff / 0 / 1/step]
211 SDK2 Certification Method *CTL [0 to 0xff / 0 / 1/step ]
220 SDK3 UniqueID *CTL [0 to 0xffffffff / 0 / 1/step]
221 SDK3 Certification Method *CTL [0 to 0xff / 0 / 1/step]