Main SP Tables-5
D117/D118 3-346 SM Appendix
When the Call Center calls out to an embedded RCG-M modem, it sends a
repeating ID tone (*#1#). This SP sets the time the line remains open to send
these ID tones after the number of the embedded RCG-M modem is dialed up
and connected.
The actual amount of time is this setting x 2 sec. For example, if you set "2"
the line will remain open for 4 sec.
163
Access Point *CTL [up to 16 / 0 / 1/step]
This is the number of the dial-up access point for RCG-M. If no setting is done
for this SP code, then a preset value (determined by the country selected) is
used.
Default: 0
Allowed: Up to 16 alphanumeric characters
164
Line Connecting *CTL
[0 to 1 / 0 / 1/step]
0: Sharing Fax
1: No Sharing Fax
This SP sets the connection conditions for the customer. This setting
dedicates the line to RCG-M only, or sets the line for sharing between RCG-M
and a fax unit.
If this setting is changed, the copier must be cycled off and on.
SP5816 187 determines whether the off-hook button can be used to
interrupt a RCG-M transmission in progress to open the line for fax
transaction.
173
Modem Serial No. *CTL [- / - / -]
This SP displays the serial number registered for the RCG-M.