Main SP Tables-2
SM Appendix 3-67 D117/D118
Appendix:
SP Mode
Tables
Displays/sets the AC current target of the charge roller for ML environment
(Middle temperature and Low humidity).
001
Environmental Target: Bk *ENG [0 to 2000 / 600 / 10uA/step]
002
Environmental Target: C *ENG [0 to 2000 / 600 / 10uA/step]
003
Environmental Target: M *ENG [0 to 2000 / 600 / 10uA/step]
004
Environmental Target: Y *ENG [0 to 2000 / 600 / 10uA/step]
2009
[Charge AC Current: MM]
Displays/sets the AC current target of the charge roller for MM environment
(Middle temperature and Middle humidity).
001
Environmental Target: Bk *ENG [0 to 2000 / 650 / 10uA/step]
002
Environmental Target: C *ENG [0 to 2000 / 650 / 10uA/step]
003
Environmental Target: M *ENG [0 to 2000 / 650 / 10uA/step]
004
Environmental Target: Y *ENG [0 to 2000 / 650 / 10uA/step]
2010
[Charge AC Current: MH]
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity).
001
Environmental Target: Bk *ENG [0 to 2000 / 650 / 10uA/step]
002
Environmental Target: C *ENG [0 to 2000 / 650 / 10uA/step]
003
Environmental Target: M *ENG [0 to 2000 / 650 / 10uA/step]
004
Environmental Target: Y *ENG [0 to 2000 / 650 / 10uA/step]
2011
[Charge AC Current: HH]
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity).
001
Environmental Target: Bk *ENG [0 to 2000 / 650 / 10uA/step]