Loading...
Main SP Tables-5
D117/D118 3-314 SM Appendix
5491 [Optional Counter]
001 Detail Option *CTL
[ - / 0x00 / 0x01/step]
bit0: Forced Job Canceling
-1:Yes, 2: No
5501 [PM Alarm]
001 PM Alarm Level *CTL
[0 to 9999 / 0 / 1/step]
0: Alarm off
1 to 9999: Alarm goes off when Value
(1 to 9999) x 1000 > PM counter
002 Original Count Alarm *CTL
[0 or 1 / 0 / 1/step]
0: No alarm sounds
1: Alarm sounds after the number of
originals passing through the ARDF >
10,000
5504 [Jam Alarm]
001
Jam Alarm *CTL
Sets the alarm to sound for the
specified jam level (document miss
feeds are not included).
[0 to 3 / 3 / 1/step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)