EasyManua.ls Logo

Ricoh D117 - HST Concentration Control: K; HST Concentration Control: Set

Ricoh D117
1207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main SP Tables-3
D117/D118 3-244 SM Appendix
026 ZnSt:Image Transfer Unit *ENG
Sets the flag for new lubricant for image
transfer unit manual settings.
[0 or 1 / 0 / 1/step]
027 Toner Sub Hopper: K *ENG
Sets the flag for new toner sub hopper
manual settings.
[0 or 1 / 0 / 1/step]
028 Toner Sub Hopper: C *ENG
029 Toner Sub Hopper: M *ENG
030 Toner Sub Hopper: Y *ENG
3710 [HST Concentration Control: Set]
001
Control Method:
Selection
*ENG
Sets the select mode if control is done or
not with HST memory.
[0 or 1 / 1 / 1/step]
0:NotUse, 1:Use
3711 [HST Concentration Control: K]
001 Vcnt *ENG Displays release check value stored in
HST memory.
[0.0 to 5.0 / - / 0.1V/step]
002 Vt *ENG
003 Sensitivity: HL *ENG
Displays release check value stored in
HST memory.
[1.22 to 3.77 / - / 0.01V/step]
004 Sensitivity: HM *ENG Displays release check value stored in
HST memory.
[0.00 to 2.55 / - / 0.01V/step]
005 Sensitivity: ML *ENG
006 Set Detection *ENG Displays release check value stored in
HST memory.
[0.0 to 5.0 / - / 0.1V/step]
007 Without Developer *ENG