Main SP Tables-3
D117/D118 3-220 SM Appendix
3529 [ProCon Interval Control :Set]
001 Gamma Corr *ENG Sets on/off for the developer gamma
correction or the environment correction
of process control execution interval.
[0 or 1 / 1:ON / 1/step]
0:OFF, 1:ON
002 Environ Corr *ENG
003 AbsHum Threshhold *ENG
Sets absolute humidity threshold for the
environment correction of process control
execution interval.
[0.0 to 99.0 / 4.3 / 0.1g/m^3/step]
004 Max Cnt Threshhold *ENG
Sets the maximum number of times for
interrupt or job end process control.
[0 to 99 / 2 / 1counts/step]
005 Exe Cnt ENG
Displays the maximum counter for
interrupt or job end process control.
[0 to 255 / - / 1 counts/step]
006 Page Cnt:BW *ENG Displays the page counter of process
control.
[0 to 5000 / - / 1sheets/step]
007 Page Cnt:FC *ENG
3530 [PowerON ProCon :Set]
001 Non-use Time Setting *ENG [0 to 1440 / 360 / 1minute/step]
002 Temperature Range *ENG [0 to 99 / 10 / 1deg/step]
003 Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step]
004 Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m^3/step]
005 Interval:BW *ENG [0 to 5000 / 250 / 1sheets/step]
006 Interval:FC *ENG [0 to 5000 / 100 / 1sheets/step]
007 Page Cnt:BW *ENG
[0 to 5000 / - / 1sheets /step]
008 Page Cnt:FC *ENG