Main SP Tables-1
SM Appendix 3-17 D117/D118
Appendix:
SP Mode
Tables
1117
[Time Control]
Adjust the amount of time for timeout.
001 Control Time1:LT *ENG [0 to 1000 / 0 / 1sec/step]
002 Control Time2:LT *ENG [0 to 1000 / 0 / 1sec/step]
003 Temp:Plain:Center1:LT *ENG [-100 to 100 / 0 / 1deg/step]
004 Temp:Plain:Press.1:LT *ENG -
005 Temp:Plain:Center2:LT *ENG [-100 to 100 / 0 / 1deg/step]
006 Temp:Plain:Press.2:LT *ENG -
007 Te m p :M -Thick:Center1 *ENG [-100 to 100 / 0 / 1deg/step]
008 Te m p :M -Thick:Press.1 *ENG [-100 to 100 / 0 / 1deg/step]
009 Te m p :M -Thick:Center2 *ENG [-100 to 100 / 0 / 1deg/step]
010 Te m p :M -Thick:Press.2 *ENG [-100 to 100 / 0 / 1deg/step]
011 Temp:Other:Center1 *ENG [-100 to 100 / 0 / 1deg/step]
012 Temp:Other:Press.1 *ENG [-100 to 100 / 0 / 1deg/step]
013 Temp:Other:Center2 *ENG [-100 to 100 / 0 / 1deg/step]
014 Temp:Other:Press.2 *ENG [-100 to 100 / 0 / 1deg/step]
021 Control Time1:A4 *ENG [0 to 1000 / 0 / 1sec/step]
022 Control Time2:A4 *ENG [0 to 1000 / 0 / 1sec/step]
023 Temp:Center1:A4 *ENG [-100 to 100 / 0 / 1deg/step]
025 Te mp:Center2:A4 *ENG [-100 to 100 / 0 / 1 deg/step]
031 Control Time1:B5 *ENG [0 to 1000 / 0 / 1 sec/step]
032 Control Time2:B5 *ENG [0 to 1000 / 0 / 1 sec/step]
033 Temp:Center1:B5 *ENG [-100 to 100 / 0 / 1 deg/step]
035 Temp:Center2:B5 *ENG [-100 to 100 / 0 / 1 deg/step]