D117/D118 6-88 SM
6.3.2 PROBLEM AT REGULAR INTERVALS
Image problems may appear at regular intervals that depend on the circumference of certain
components.
The following diagram shows the possible symptoms (black or white dots at regular intervals).
[A]: Paper feed direction
[B]: Problems at regular intervals
Abnormal image at 33.6-mm intervals: Charge roller
Colored spots at 40.82-mm intervals: Image transfer roller
Colored spots at 20.9-mm intervals: Development roller
Abnormal image at 55.4 (center) or 55.0 (end)-mm intervals: Paper transfer roller
Colored spots at 75.4-mm intervals: OPC drum
Spots at 78.5-mm intervals: Pressure roller
Spots at 78.5-mm intervals: Fusing belt
6.3.3 BLANK PRINT
Symptom Possible cause Necessary actions
No image is printed.
Defective laser unit Replace the laser unit.
Defective PCDU Replace the PCDU.
Defective image transfer
belt unit
Replace the image transfer
belt unit.
Incorrect action of paper
transfer roller
Check the guide and the
paper transfer roller.
Defective HVPS Replace HVPS.
Defective BICU Replace the BICU.