Main SP Tables-2
D117/D118 3-70 SM Appendix
003
Judge Interval *ENG [0 to 500 / 10 / 1 page/step]
004
Temp Condition *ENG [0 to 99 / 35 / 1 deg/step]
005
Relative Humidity Condition *ENG [0 to 99 / 50 / 1%RH/step]
006
Absolute Humidity Condition *ENG [0 to 99 / 12 / 1 g/m
3
/step]
007
Temp. Change: Threshold M *ENG [0 to 99 / 10 / 1 deg/step]
008
Relative Humidity Change:
Threshold M
*ENG [0 to 99 / 50 / 1%RH/step]
009
Absolute Humidity Change:
Threshold M
*ENG [0 to 99 / 6 / 1 g/m
3
/step]
010
Temp. Change: Threshold S *ENG [0.0 to 20.0 / 1.0 / 0.1deg/step]
011
Relative Humidity Change:
Threshold S
*ENG [0 to 50 / 5 / 1%RH /step]
012
Absolute Humidity Change:
Threshold S
*ENG [0.0 to 20.0 / 1.0 / 0.1 g/m
3
/step]
013
Alone Time *ENG [0 to 1440 / 360 / 10min./step]
014
Coefficient of Correction *ENG [0.00 to 2.00 / 0.70 / 0.01 kV/mA/step]
2015
[Charge AC Adjustment:]
Displays a result of the AC charge adjustment.
001
Result K Plain Bk *ENG
[0 to 9 / 0 / 1/step]
002
Result C Plain C *ENG
003
Result M Plain M *ENG
004
Result Y Plain Y *ENG
2016 [ZnSt Application Mode]
001 Temperature Threshold(L) *ENG [0 to 50 / 15 / 1 deg/step]
002 Temperature Threshold(H) *ENG [0 to 50 / 30 / 1 deg/step]