Main SP Tables-3
SM Appendix 3-197 D117/D118
Appendix:
SP Mode
Tables
003
Thresh Num of
UpperCounter
*ENG
Sets the number of times to exceed the
Vt upper limit threshold to determine the
Vt upper limit error (SC360 to 363).
[0 to 500 / 280 / 1times/step]
004 Lower Threshold *ENG
Sets Vt upper lower threshold to detect
lower limit error.
[0.00 to 5.00 / 0.50 / 0.01V/step]
005
Threshold Num of
LowerCounter
*ENG
Sets the number of times to fall below the
Vt lower limit threshold to determine the
Vt lower limit error (SC365 to 368).
[0 to 500 / 140 / 1times/step]
011 Upper Counter: Bk *ENG
Displays the number of times that Vt for
each color exceeds to Vt upper limit
threshold.
[0 to 500 / - / 1 times /step]
012 Upper Counter: C *ENG
013 Upper Counter: M *ENG
014 Upper Counter: Y *ENG
021 Lower Counter: Bk *ENG
Displays the number of times that Vt for
each color falls below to Vt lower limit
threshold.
[0 to 500 / - / 1 times /step]
022 Lower Counter: C *ENG
023 Lower Counter: M *ENG
024 Lower Counter: Y *ENG
3212 [Vt Shift :Set]
011 Low Spd:K *ENG
Sets the correction value at low speed to
correct Vt shift for each color.
[0.00 to 5.00 / 0.31 / 0.01V/step]
012 Low Spd:C *ENG
013 Low Spd:M *ENG
014 Low Spd:Y *ENG