EasyManua.ls Logo

Ricoh D117 - MUSIC Start Time

Ricoh D117
1207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main SP Tables-2
SM Appendix 3-95 D117/D118
Appendix:
SP Mode
Tables
Displays the time (hour) of the last MUSIC execution
005
Minute *ENG [0 to 59 / - / 1 minute/step]
Displays the time (minute) of the last MUSIC execution.
006
Temperature *ENG [0 to 100 / - / 1 deg/step]
Displays the temperature of the last MUSIC execution.
007 Execution Result *ENG
[0 or 1 / 0 / 1/step]
0: Completed successfully, 1: Failed
008 Number of Execution *ENG [0 to 999999 / - / 1 times/step]
009 Number of Failure *ENG [0 to 999999 / - / 1 times/step]
010 Error Result: C *ENG [0 to 9 / - / 1/step]
0: Not done
1: Completed successfully
2: Cannot detect patterns
3: Fewer lines on the pattern than the target
4: Out of the adjustment range
5 to 9: Not used
011 Error Result: M *ENG
012 Error Result: Y *ENG
013 Error Result: K *ENG
014 Temperature 2 *ENG [-10 to 100 / - / 1deg/step]
015 Te mperature 3 *ENG [-10 to 100 / - / 1deg/step]
2197 [MUSIC Start Time]
001
MUSIC Start Time
(EDT)
*ENG [10 to 40 / 20 / 10ms/step]
002 TM Sensor Position *ENG [50.00 to 500.00 / 379.69 / 0.01mm/step]