Main SP Tables-7
SM Appendix 3-399 D117/D118
Appendix:
SP Mode
Tables
014 Image Transfer Cleaning Unit
015 Fusing Unit
016 Paper Transfer Roller Unit
017 Waste Toner bottle
018 Fusing Roller
019 Pressure Roller
7801
[ROM No/ Firmware Version]
Displays all versions and ROM numbers in the machine.
CTL
[-]
255 Firmware Version
7803 [PM Counter Display] (Page, Unit, [Color])
001 to
027
Displays the number of sheets printed for each current maintenance unit.
PM counters click up based on the number of A4 (LT) LEF size sheets printed.
Therefore, the A3 (DLT) Double Count is activated. The Double Count cannot
be deactivated.
When a unit is replaced, the machine automatically detects that the new unit is
installed.
Then, the current PM counter value is automatically moved to the PM Counter –
Previous (SP7-906-1 to 10) and is reset to “0”.
The total number of sheets printed with the last unit replaced can be checked
with SP7-906-1 to 10.
The LCT is counted as the 3rd feed station.
*CTL: 001
ENG: Other than 001
[0 to 9999999 / - / - page/step]
001 Paper
002 Page: PCU: K