Main SP Tables-3
D117/D118 3-206 SM Appendix
015 Ifsg UpperLimit *ENG
Set error detection threshold for SC382
("If" upper limit error).
[0.0 to 50.0 / 30.0 / 0.1mA/step]
020 Interval :Set *ENG
Sets Vsg adjustment execution Page
interval determined during printing or at
the end of printing.
Note: Vsg adjustment is executed when
process control or MUSIC requires the
execution. (Not executed by it.)
[0 to 2000 / 500 / 1page/step]
021 Page Cnt *ENG
Displays Page counter used Vsg
execution determination.
[0 to 2000 / - / 1page/step]
3321 [Adjusted Vsg]
001 Vsg reg *ENG
Displays normal reflection light output
from bared belt with Vsg adjustment.
[0.00 to 5.50 / - / 0.01V/step]
011 Vsg dif *ENG
Displays diffused reflection light output
from bared belt with Vsg adjustment.
[0.00 to 5.50 / - / 0.01V/step]
021 Vsg reg(BW) *ENG
Displays normal reflection light output
from bared belt with Vsg adjustment.
[0.00 to 5.50 / - / 0.01V/step]
031 Vsg dif(BW) *ENG
Displays diffused reflection light output
from bared belt with Vsg adjustment.
[0.00 to 5.50 / - / 0.01V/step]
041 Vsg TM(Front) *ENG Displays normal reflection light output
from bared belt with Vsg adjustment
(TM_Front, TM_Center or TM_Rear
sensor).
[0.00 to 5.50 / - / 0.01V/step]
042 Vsg TM(Center) *ENG
043 Vsg TM(Rear) *ENG