Maintenance Tables
SM Appendix 2-1 D117/D118
Appendix:
Preventive
Maintenance
Tables
2. PREVENTIVE MAINTENANCE TABLES
2.1 MAINTENANCE TABLES
2.1.1 PREVENTIVE MAINTENANCE ITEMS
Yield Parts
The parts mentioned in these tables have a target yield. However, the total copy/print volume
made by the machine will not reach the target yield within the machine's targeted lifetime if the
machine is used under the target usage conditions (ACV, color ratio, P/J, and C/O). So, these
parts are categorized not as PM parts but as yield parts (EM parts). The parts with “(R)” in this
table are yield parts.
Chart: A4 (LT)/5%
Mode: 2 copies / original (prints/job)
Ratio 20%
Environment: Normal temperature and humidity
Yield may change depending on circumstances and print conditions.
Symbol keys: C: Clean, R: Replace, L: Lubricant, I: Inspect
Mainframe
Item 45K 60K 90K 120K 240K EM Remarks
Scanner
Exposure Glass C
Ricoh exposure
glass cleaner
ADF Exposure Glass C
Ricoh exposure
glass cleaner
PCDU
PCDU (K) R
Transfer
Image Transfer Belt Unit (R)
Rev. 09/12/2014