Main SP Tables-2
D117/D118 3-186 SM Appendix
2975 [B/W Image Request Timing]
001 T14_2: standard speed *ENG [0 to 4000 / 0 / 10/msec/step]
003 T14_2: low speed *ENG [0 to 4000 / 0 / 10/msec/step]
2990 [Print Duty Control]
001
Duty Control State *ENG [0 or 1 / - / 1/step]
Displays the Duty limitation status of the current printing.
0: Not limited
1: Limited
002
Exec Interval: Duty Control *ENG [30 to 3600 / 30 / 10sec/step]
Sets the determination time interval to determine if the printing Duty limitation is
executed or not.
004
Forced CPM Down Thresh:
No Duty Control
*ENG [0 to 5000 / 0 / 1page/step]
Sets the forced shutdown threshold when the printing Duty is not limited.
005
BK Drum Stop Time: No Duty
Control
*ENG
[0 to 65535 / 0 / 10msec/step]
006
Col Drum Stop Time: No Duty
Control
*ENG
007
Forced CPM Down Thresh:
Duty Control
*ENG [0 to 5000 / 3 / 1page/step]
Sets the forced shutdown threshold when the printing Duty is limited.
008
BK Drum Stop Time: Duty
Control
*ENG [0 to 65535 / 0 / 10msec/step]
009
Col Drum Stop Time: Duty
Control
*ENG [0 to 65535 / 32000 / 10msec/step]