EasyManua.ls Logo

Ricoh D117 - Touch Panel Position Adjustment

Ricoh D117
1207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Exterior Covers
SM 4-29 D117/D118
Replacement
and
Adjustment
4.4.9 TOUCH PANEL POSITION ADJUSTMENT
It is necessary to calibrate the touch panel at the following times:
When you replace the operation panel.
When you replace the controller board.
When the touch panel detection function does not operate correctly
Do not use items [2] to [9] on the Self-Diagnostic Menu. These items are for design use only.
1. Press
, press the "1" "9" "9" "3" keys, press the "Clear/Stop" key 5 times to open the
Self-Diagnostics menu.
2. On the touch screen press “Touch Screen Adjust” (or press the "1" key).
3. Use a pointed (not sharp) tool to press the upper left mark
.
4. Press the lower right mark when “
” shows.
5. Press [#] OK on the screen (or press
) when you are finished.
6. Touch [#] Exit on the screen to close the Self-Diagnostic menu. Save the calibration settings.