Loading...
Main SP Tables-5
SM Appendix 3-345 D117/D118
Appendix:
SP Mode
Tables
154
Outside Line Outgoing
Number
*CTL [4digits / - / 1digit/step]
The SP sets the number that switches to PSTN for the outside connection for
embedded
RCG-M in a system that employs a PBX (internal line).
If the execution of SP5816-151 has succeeded and embedded RCG-M
has connected to the external line, this SP display is completely blank.
If embedded RCG-M has connected to an internal line, then the number
of the connection to the external line is displayed.
If embedded RCG-M has connected to an external line, a comma is
displayed with the number. The comma is inserted for a 2 sec. pause.
The number setting for the external line can be entered manually
(including commas).
155
156
Dial Up User Name *CTL [up to 32 char. / - / 1char/step]
Use this SP to set a user name for access to remote dial up. Follow these
rules when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
157
Dial Up Password *CTL [- / - / -]
Use this SP to set a password for access to remote dial up. Follow these rules
when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
161
Local Phone Number *CTL [up to 24 / - / 1/step]
Use this SP to set the telephone number of the line where embedded RCG-M
is connected. This number is transmitted to and used by the Call Center to
return calls. Limit: 24 numbers (numbers only)
162
Connection Timing
Adjustment Incoming
*CTL [0 to 24 / 1 / 1/step]