EasyManua.ls Logo

Ricoh D117 - Skew Adjustment; TM;ID Sensor Check Result; TM;ID Sensor Test

Ricoh D117
1207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main SP Tables-2
SM Appendix 3-77 D117/D118
Appendix:
SP Mode
Tables
2112
[TM/ID Sensor Test]
This SP is used to check the ID sensors at the factory. The results of this SP
are displayed in SP2140 to SP2145.
001 TM/ID Sensor Check ENG
[- / - / -]
[Execute]
010 General:FCRP *ENG [0 to 9999 / - / 1/step]
020 Threshold Setting *ENG [0.00 to 5.50 / 1.90 / 0.01V/step]
2117
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C, Y or Bk.
001 Ma:Skew Adjustment *ENG
[–256 to 256 / 0 / 1 click/step]
002 Cy:Skew Adjustment *ENG
003 Ye:Skew Adjustment *ENG
004 Bk:Skew Adjustment *ENG
2140
[TM/ID Sensor Check Result]
Displays the maximum result values of the ID sensor check.
Front, Center, Rear: ID sensors for the automatic line position adjustment and
the process control
001 PWM: ID Sensor *ENG
[0 to 1024 / - / 1/step]
005 PWM: Front *ENG
006 PWM: Center *ENG
007 PWM: Rear *ENG