Main SP Tables-1
D117/D118 3-56 SM Appendix
007
Heater OFF Time:After State
Shift
*ENG [0 to 20000 / 0 / 1msec/step]
1134
[Effective Duty Adjustment]
Switches effective fixed duty level and power control for adjustment.
001 Control Method Switch *ENG
[0 or 1 / 1: ON / 1/step]
0: OFF
1: ON
1141
[Fusing SC Issue Time Info]
Displays the time when an SC code was issued.
001
SC Number *ENG [0 to 99999 / - / 1/step]
101
Htg Roller Temp1 *ENG [-50 to 260 / -/ 1deg/step]
104
Htg Roller Temp1 *ENG [-50 to 260 / - / 1deg/step]
107
Press Roller Temp Value1 *ENG [-50 to 260 / - / 1deg/step]
108
Press Roller.End Temp
Value1
*ENG [-50 to 260 / - / 1deg/step]
151
Htg Roller Temp2 *ENG [-50 to 260 / - / 1deg/step]
154
Htg Roller Temp2 *ENG [-50 to 260 / - / 1deg/step]
157
Press Roller Temp Value2 *ENG [-50 to 260 / - / 1deg/step]
158
Press Roller.End Temp
Value2
*ENG [-50 to 260 / - / 1deg/step]
201
Htg Roller Temp3 *ENG [-50 to 260 / - / 1deg/step]
204
Htg Roller Temp3 *ENG [-50 to 260 / - / 1deg/step]