EasyManua.ls Logo

Ricoh D117 - Fusing Temperature Display (Heating or Pressure); Standby Target Temp. Setting

Ricoh D117
1207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Main SP Tables-1
D117/D118 3-12 SM Appendix
1106
[Fusing Temp. Display] Fusing Temperature Display (Heating or Pressure)
Displays the current temperature of the heating and pressure rollers.
001 Center ENG [-50 to 250 / 0 / 1deg/step]
002
End ENG [-20 to 348 / 0 / 1deg/step]
The heating roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
003
Pressure: Center ENG [-20 to 250 / 0 / 1deg/step]
The pressure roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
005 Pressure: End ENG [-20 to 250 / 0 / 1deg/step]
1107 [Standby Target Temp. Setting]
001
Stanby/Preheat1:Center *ENG [0 to 100 / 60 / 1deg/step]
Specifies the time that the fusing heater turns off after the fusing unit
temperature has reached its target temperature.
003
Preheat2:Center *ENG [-50 to 100 / -50 / 1deg/step]
Specifies the temperature of the heating roller for the ready or energy save 2
mode.
005
Low Power:Center *ENG [-50 to 100 / -50 / 1deg/step]
Specifies the temperature of the heating roller for the low power mode.
007
Print Ready:Center *ENG [0 to 180 / 150 / 1deg/step]
Specifies the temperature of the heating roller for the print ready condition.

Table of Contents