D117/D118 4-46 SM
Examples:
If the SP value is +7, turn knob [A] 7 clicks clockwise,.
If the SP value is -6, turn knob [A] 6 clicks counterclockwise.
7. Reassemble the machine.
Never touch the LD units when the upper cover is attached. Otherwise, the LD unit
may move, and you may adjust the color skew again.
8. Check the SPs (SP2-117-001 to 004). If even one of them is over 5 (either positive or
negative), repeat steps 1, 2, 3 and 6. The adjustment is finished if all SP values are within ±5.
4.6.3 LD UNIT COOLING FAN
1. Scanner Unit ( p.4-30)
2. LD unit cooling fan [A] (
x 1)