Main SP Tables-2
SM Appendix 3-187 D117/D118
Appendix:
SP Mode
Tables
010 Correction Coefficient *ENG [-1.0 to -1.0 / -0.5 / 0.1/step]
011
Execution Temp. Threshold *ENG [20.0 to 70.0 / 42.0 / 0.1deg/step]
Sets the temperature threshold to execute the printing Duty limitation.
0: Not execute
012
Cancellation Temp.
Threshold
*ENG [0.0 to 20.0 / 1.0 / 0.1deg/step]
Sets the temperature threshold (differences with the temperature of the printing
Duty limitation execution) to cancel the printing Duty limitation.
013
ON/OFF setting *ENG [0 or 1 / 1 / 1/step]
Control or not control the printing Duty limitation.
0: Not control
1: Control